The 50/60 Hertz versions range from 300va/200w through 900va/600w.
UPS Standard Floor Models
UPS Medical Grade Floor Mount "ONm" Models
![]() Home Page |
![]() Software Kits |
![]() 60 Hz 120v UPS |
![]() 50/60 Hz 230v UPS |
![]() 50/60 Hz On-Line |
![]() Estimated Run Times |
![]() Terms Defined |
![]() Model Index |
| MODELS: | UPS Standard Floor Mount |
| TYPE: | Multi Phase, 50/60 Hertz |
| VOLTAGE: | 120 |
| RATINGS: | 400-900VA |
| 3.3-7.5A | |
| 250-600W |
These models come in a variety of plug and receptacle configurations other than those listed. Contact your Gryphon representative for help with your specific application.
| MODEL | ON400J | 0N900J |
|---|---|---|
| Output Rating (VA) | 400 | 900 |
| Output Rating (W) | 250 | 600 |
| Frequency (Hz) | 50/60 | 50/60 |
| Input/Output Voltage (VAC) | 120 | 120 |
| Output Wave Form | Sine | Sine |
| Load Regulation (RMS) | ±3% | ±3% |
| Inrush - ½ cycle (Amps) | 100 | 200 |
| Surge Current (Amps) 1 sec. Typical | 20 | 40 |
| Surge Current (Amps) 4 sec. Typical | 10 | 20 |
| MODEL | ON400J | 0N900J |
| 1kHz Forward Transfer Impedance (Ohms) | <5 | <3 |
| Recharge to 60% Capacity (hrs) | 4 | 4 |
| Efficiency (%) | >90 | >83 |
| Agency Approvals | UL1778 & CSA22.2 | |
| Line Cord (Feet) | 6 | 6 |
| Input Connector (IEC) | 320 | 320 |
| Width (Inches) | 8.3 | 8.3 |
| Height (Inches) | 7.5 | 12 |
| Depth (Inches) | 15.5 | 18.5 |
| Shipping Weight (Lbs.) | 42 | 68 |
| MODEL | ON400J | 0N900J |
![]() Home Page |
![]() Top of Page |
![]() Software Kits |
![]() 60 Hz 120v UPS |
![]() 50/60 Hz 230v UPS |
![]() 50/60 Hz On-Line |
![]() Estimated Run Times |
![]() Terms Defined |
![]() Model Index |
| MODELS: | UPS Medical Grade Floor Mount "ONm" Type |
| TYPE: | Multi Phase, 50/60 Hertz |
| VOLTAGE: | 120 |
| RATINGS: | 300VA |
| 2.5A | |
| 200W |
This model comes in a -SI version which has basic communication capabilities built in.
Contact your Gryphon representative for help with your specific application.
| MODEL | 0Nm300DJ |
|---|---|
| Output Rating (VA) | 300 |
| Output Rating (W) | 200 |
| Frequency (Hz) | 50/60 |
| Input/Output Voltage (VAC) | 120 |
| Output Wave Form | Pseudo-Sine |
| Full Load Backup Time (min) | 15 |
| Load Regulation (RMS) | ±3% |
| Recharge to 60% Capacity (hrs) | 6-10 |
| Leakage Current (µamps) | <300 |
| MODEL | 0Nm300DJ |
| Agency Approvals | FCC Class B, UL1778, UL2601, CSA22.2 (No. 601.1) |
| Input Connector | IEC320 |
| Input Cord | Use the cord from the protected piece of equipment. |
| Load Connector | 4@IEC320 |
| Load Cord | 6' with IEC320 connectors at each end |
| Width (Inches) | 6 |
| Height (Inches) | 7.4 |
| Depth (Inches) | 15 |
| Shipping Weight (Lbs.) | 40 |
| MODEL | 0Nm300DJ |
![]() Home Page |
![]() Top of Page |
![]() Software Kits |
![]() 60 Hz 120v UPS |
![]() 50/60 Hz 230v UPS |
![]() 50/60 Hz On-Line |
![]() Estimated Run Times |
![]() Terms Defined |
![]() Model Index |